Reference 01503 · Patient simulator
Heartworks dual - TTE and TEE ultrasound
This is a configuration of HEARTWORKS - Echocardiography and cardiac anatomy simulator
- Patient simulator
- Cardiology
- Configuration
- Medicine
The complete simulation solution for Transesophageal (TEE) and Transthoracic Echocardiography (TTE) in one single dual purpose manikin.
Price on request
Available in Spain, Portugal and Andorra · delivery time given in the proposal
Downloadable data sheet — features, specifications and delivery time, in PDF.
Need a technical report? Ask us for it and we'll send it within 24 h →
Description
What this equipment is and what it's designed for.
The complete simulation solution for Transesophageal (TEE) and Transthoracic Echocardiography (TTE) in one single dual purpose manikin.
A ‘plug and play’ solution, tutors can easily switch between TEE and TTE in their training schedules. Retaining all the features of the acclaimed HeartWorks imaging software, educational programs can be both cost and time efficient without compromising on quality.
What you learn
Patient simulator modality. The competencies this equipment trains, in the language of the training plan.
- Learn cardiac anatomy
- Practise TEE & TTE probe manipulation skills
- Acquire quality diagnostic images
- Relate ultrasound images to anatomy concurrent with probe manipulation
- Recognise pathology
- 2D, Doppler & M-mode imaging
Related procedures: Ultrasound
Cases and pathologies
The clinical scenarios that can be simulated with this equipment.
- Global left ventricular dysfunction, Left ventricular anterior wall motion abnormality and Hypovolemia
- Aortic stenosis, Mitral stenosis and Mitral regurgitation
- Aortic dissection, Atrial septal defect and Mitral regurgitation doppler
- Mechanical aortic valve, Right ventricular dusfunction with tricuspid regurgitation and Aortic stenosis and mitral stenosis Doppler
- Unilobed left arial appendage, Multilobed left arial appendage and Hooked left arial appendage
- Normal lung, Pleural effusion and Cardiac tamponade
- Aortic regurgitation, Pneumothorax and Hypovolemia with doppler
- Pukmonary embolus, Left atrial appendage occlusion devices and Lateral flexion
- Interactive learning of cardiac anatomy, Intuitive management of imaging modes when making measurements and Realistic virtual ultrasound console
- Measurements, calculations and reports
- Hypertrhophic cardiomyopathy, Right coronary artery regional wall motion abnormality and Mitral and tricuspid regurgitation
- Biplane imaging
Features and what's included
What the equipment does and what comes in the box, as described by the manufacturer.
Features
TWO SIMULATORS IN ONE:- TEE SIMULATOR: A comprehensive education in transesophageal echocardiography.
- TTE SIMULATOR: A comprehensive education in transthoracic echocardiography.
- Slicing and removing sections of the beating, interactive 3D heart model reveals underlying structures that have been annotated, labelled and described.
- An integrated text book facilitates a comprehensive understanding of cardiac anatomy.
- Authentic controls on the TEE probe in a life-size torso manikin and palpable, anatomical landmarks on the chest for TTE probe manipulation enable accurate, real-time views of both the 3D anatomical heart and related ultrasound planes.
- Offering all the features of the HeartWorks imaging software, when practising and developing probe handling skills, students will see 3D heart images and corresponding real-time ultrasound views, so that image relationships can be visualised and interpreted.
- The integrated anatomical cardiac text book provides an additional valuable resource in echocardiography education.
- Colour and spectral Doppler modalities are available along with the tools with which to make accurate quantitative assessment of cardiac function.
- Pulsed and continuous wave Doppler information can be obtained from any intra-cardiac region.
Includes
- Transthoracic and transoesophageal echocardiography, both probes
Services for this equipment
Services matter: the equipment gets commissioned, the staff know how to use it and maintenance is settled before you start. Include them in your budget and avoid having to raise a second purchase.
- Preventive maintenance We'll let you know when it's due
Documentation
You can download it now or we'll send it on request.
Other related equipment
They train the same technique. Each one approaches it in its own way: none of them replaces this one.
-
BODYWORKS EVE - PoCUS, TTE and TEE ultrasound simulator
See details →
-
HEARTWORKS - Echocardiography and cardiac anatomy simulator
See details →
-
ULTRASOUND MENTOR - Ultrasound simulator
See details →
-
AERIS - Portable PoCUS ultrasound simulator with 1-year licence
See details →
-
BABYWORKS - Paediatric and neonatal ultrasound simulator
See details →
-
NEEDLE TRAINER - Ultrasound-guided procedures simulator
See details →
Is this equipment going into a new centre?
If you're equipping a classroom or a whole centre, starting from the shopping list works out expensive. Start from the needs assessment.