Reference 01305 · Patient simulator
NOELLE & NEWBORN - Obstetrics and neonatal resuscitation - UNI
- Patient simulator
- Emergencies
- Main product
- Medicine
The NOELLE® and Newborn package is a complete simulation-based obstetric care and neonatal resuscitation education and training solution. This turnkey solution includes a NOELLE childbirth patient simulator, a full-term newborn, UNI® 3 control Laptop PCs, a Vitals® patient monitor, Labour & Delivery Simulation Learning Experience® Courseware package, and accessories.
Price on request
Available in Spain, Portugal and Andorra · delivery time given in the proposal
Downloadable data sheet — features, specifications and delivery time, in PDF.
Need a technical report? Ask us for it and we'll send it within 24 h →
Description
What this equipment is and what it's designed for.
The NOELLE® with the Newborn Package is a full-value solution, ready to use, designed to help students and staff develop the skills to manage antepartum complications, routine and high-risk deliveries, and postpartum emergency scenarios, as well as neonatal resuscitation and stabilisation.
What you learn
Patient simulator modality. The competencies this equipment trains, in the language of the training plan.
- Resuscitation training (CPR)
- Seizure management
- Post-partum hemorrhage management
- Palpation of pulses
- Normal, breech and vertex deliveries
- Obstetric emergencies skills training
- Fetal heart auscultation
- Oral intubation
- IV training
- BVM ventilation
- Neonatal heart and lung sounds auscultation
- Cyanosis management
Related procedures: Childbirth · Neonatal resuscitation
Cases and pathologies
The clinical scenarios that can be simulated with this equipment.
- The new NOELLE Labor & Delivery Simulation Learning Experiences (SLEs) provide you with a library of 9 ready-to-use, evidence-based scenarios designed to help you maximize participant’s learning through outcome-focused simulated clinical patient encounters.
- Amniotic Fluid Embolism
- Breech Vaginal Delivery
- Magnesium Toxicity
- Normal Vaginal Delivery
- Placental Abruption
- Postpartum Hemorrhage
- Preeclampsia
- Prolapsed Cord
- Shoulder Dystocia
- The new TORY® Neonatal Care Simulation Learning Experiences (SLEs) provide you with a library of ready-to-use, evidence-based scenarios designed to help you maximize participant’s learning through outcome-focused simulated clinical patient encounters.
- Acute Respiratory Distress Syndrome
- Bronchopulmonary Dysplasia with Pulmonary Hypertension
- Drug-Exposed Infant/Neonatal Abstinence Syndrome
- Early-Onset Sepsis
- Late-Onset Sepsis
- Nuchal Cord
- Pneumonia
- Shoulder Dystocia
Features and what's included
What the equipment does and what comes in the box, as described by the manufacturer.
Features
NOELLE®:- Full-size NOELLE® maternal patient simulator
- Full-term intubatable newborn
- 9 Labour and Delivery SLEs
- Facilitator’s Guidebook
- Maternal speech
- Normal, miosis (constricted), and mydriasis (blown) pupil states
- Independent left/right pupil states simulate consensual and nonconsensual response
- eCPR® measures and logs compressions and ventilations
- Maternal vital signs monitor
- Fetal heart tones and neonatal vital signs monitor
- Precision delivery system
- Programmable normal, breech, shoulder dystocia, and C-section
- Programmable eclampsia w/seizures
- Intubatable airway with chest rise
- IV arms for meds/fluids
- Removable stomach cover
- Force and fetal shoulder position measured and graphed in real time
- Programmable postpartum haemorrhage
- Birthing fetus with placentas and umbilical cords
- Bilateral radial pulses
- Full-term intubatable newborn with cyanosis and pulses
- eCPR® measures and logs compressions and ventilations
- Realistic heart and lung sounds
- Realistic crying
- Touchscreen all-in-one PC preloaded with Vitals®
- Display up to 8 vital parameters including HR, ABP, RR, CO2, SpO2, temperature, NIBP, and time
- Select up to 5 dynamic waveforms including ECG II, ABP, respiration, CO2, and pulse oximetry
- Perinatal monitor with programmable uterine activity and fetal heart rate
- UNI® 3 Laptop PC
- USB module with connection to NOELLE® and her Newborn
- Wireless communications between laptop and touchscreen monitors
- Full-size NOELLE® maternal and neonatal birthing simulator with eclampsia and haemorrhage capabilities
- Preprogrammed speech
- eCPR™ Real-time feedback
- Maternal vital signs monitor
- Fetal heart tones and neonatal vital signs monitor
- Set up and run OB simulations for normal labour and birth, variations on normal, shoulder dystocia, breech
- presentation, preeclampsia, cord prolapse, uterine rupture, peripartum haemorrhage, anaphylactoid syndrome of pregnancy, and preterm labour and birth
- Intubatable airway with chest rise
- IV arms for meds/fluids
- Removable stomach cover
- Programmable eclampsia w/seizures
- Precision delivery system
- Force and fetal shoulder position measured and graphed in real-time
- Programmable postpartum haemorrhage
- Birthing fetus with placentas and umbilical cords
- Bilateral radial pulse
- Full-term intubatable newborn with cyanosis and pulses
- eCPR® measures and logs compressions and ventilations
- Realistic heart and lung sounds
- Realistic crying
- Real patient monitoring support allows participants to set up and operate real equipment, interpret real-time data, and follow protocols just as they would in real situations.
- Supports operation on-the-fly or by way of programmable scenarios
- ECG monitoring
- ECG-derived respiration monitoring
- Pre- and post-ductal SpO2monitoring
- Oscillometric NIBP
- Live pacing and defibrillation
- Capnography
- It simulates the functionality and look of a real patient monitor, allowing participants to practice data interpretation, documentation, and clinical decision-making skills.
- Customizable interface can mimic the look of various real patient monitor brands
- 20+ Dynamic scalars and waveforms including HR, ABP, SpO2, RR, EtCO2, temperature, time, and more
- Customizable alarms for vital sign parameter high/low threshold
- Virtual 12-Lead ECG Monitoring
- Data histogram
- Built-in virtual defibrillator and pacer
- Wireless data communication
Includes
- 1 NOELLE simulator
- 1 Newborn patient simulator
- 1 UNI tablet pc (simulation controller)
- 9 Pre-installed Labor and Delivery simulation scenarios
- 1 Virtual patient monitor with Vitals
- 1 Soft carrying case
- 1 Instructions Manual
Modules
They extend what this equipment teaches. They are requested separately and are not included in the quotation by default.
- It simulates the functionality and look of a real patient monitor, allowing participants to practice data interpretation, documentation, and clinical decision-making skills.
- Customizable interface can mimic the look of various real patient monitor brands
- 20+ Dynamic scalars and waveforms including HR, ABP, SpO2, RR, EtCO2, temperature, time, and more
- Customizable alarms for vital sign parameter high/low threshold
- Virtual 12-Lead ECG Monitoring
- Data histogram
- Built-in virtual defibrillator and pacer
- Wireless data communication
Services for this equipment
Services matter: the equipment gets commissioned, the staff know how to use it and maintenance is settled before you start. Include them in your budget and avoid having to raise a second purchase.
- Preventive maintenance We'll let you know when it's due
Documentation
You can download it now or we'll send it on request.
Other related equipment
They train the same technique. Each one approaches it in its own way: none of them replaces this one.
-
NOELLE and PEDI Blue Neonate - Simulator for birthing training - OMNI
See details →
-
NOELLE - Standard birthing simulator - OMNI1
See details →
-
C.H.A.R.L.I.E. Neonatal Resuscitation Simulator Without Interactive ECG Simulator
See details →
-
Complete „Lucy“ Maternal and Neonatal Birthing Simulator
See details →
-
Full term birthing baby rohan
See details →
-
Full-term baby simulator for delivery and care - BABY TOBY
See details →
Is this equipment going into a new centre?
If you're equipping a classroom or a whole centre, starting from the shopping list works out expensive. Start from the needs assessment.