Use on any large-sized manikin to change it into a 12-lead trainer. Pace and defibrillate directly on the overlay system connected to the interactive 12-lead ECG simulator.
Price on request
Available in Spain, Portugal and Andorra · delivery time given in the proposal
Downloadable data sheet — features, specifications and delivery time, in PDF.
Need a technical report? Ask us for it and we'll send it within 24 h →
Description
What this equipment is and what it's designed for.
Use on any large-sized manikin to change it into a 12-lead trainer. Pace and defibrillate directly on the overlay system connected to the interactive 12-lead ECG simulator.
Training features:
- Four preset pacing capture levels: 70, 80, 90 or 100mA. Waveforms for pacing: Sinus Brady (two), 1st degree A-V block, 2nd degree type I A-V block, 2nd degree type II A-V block, 2nd degree type II A-V block with PVCs, and 3rd degree A-V block.
- Waveforms for defibrillator training: V. Fib, V. Tach (high rate), V. Tach (low rate), Torsade, A. Fib, A. Flutter, zPSVT, Sinus Tach, Sinus rhythm, Sinus rhythm with PVCs, and Asystole.
- ST segments and T wave of abnormalities: Anterior MI, Inferior MI, Antero-Septal ST elevation, Anterior ST depression, Lateral ST elevation, and Inferior ST elevation.
What you learn
Device simulator modality. The competencies this equipment trains, in the language of the training plan.
- Placement of the electrodes for a 12-lead ECG
- Interpretation of rhythms and conduction disorders
- Defibrillation directly on the manikin overlay
- Transcutaneous pacing and checking for capture
- Recognition of ST segment and T wave changes
- Selection of the energy and the pacing output
Related procedures: Advanced life support · Electrocardiography · Patient monitor
Cases and pathologies
The clinical scenarios that can be simulated with this equipment.
- Sinus bradycardia
- First degree atrioventricular block
- Second degree atrioventricular block, type I and type II
- Third degree atrioventricular block
- Ventricular fibrillation and ventricular tachycardia at high and low rates
- Torsade de pointes
- Atrial fibrillation and atrial flutter
- Paroxysmal supraventricular tachycardia and sinus tachycardia
- Sinus rhythm with ectopic beats, and asystole
- Anterior and inferior myocardial infarction, with ST segment elevation or depression
Features and what's included
What the equipment does and what comes in the box, as described by the manufacturer.
Features
- Compatible with any large-size manikin, which it turns into a 12-lead trainer
- Allows capture and defibrillation directly on the overlay system
- Connects to the interactive 12-lead ECG simulator
- Four preset capture levels: 70, 80, 90 or 100 mA
Services for this equipment
Services matter: the equipment gets commissioned, the staff know how to use it and maintenance is settled before you start. Include them in your budget and avoid having to raise a second purchase.
- Preventive maintenance We'll let you know when it's due
Documentation
You can download it now or we'll send it on request.
Other related equipment
They train the same technique. Each one approaches it in its own way: none of them replaces this one.
Is this equipment going into a new centre?
If you're equipping a classroom or a whole centre, starting from the shopping list works out expensive. Start from the needs assessment.