Reference 11562 · Task trainer
Neonatal Resuscitation Simulator
- Task trainer
- Emergencies
- Main product
- Medicine
This simulator is a realistic full-term male newborn baby with anatomical accuracy and product features designed to focus on the critical resuscitation skills required in the first ten minutes of a newborn’s life, it meets the key components of the Neonatal Resuscitation Program and most other…
Price on request
Available in Spain, Portugal and Andorra · delivery time given in the proposal
Downloadable data sheet — features, specifications and delivery time, in PDF.
Need a technical report? Ask us for it and we'll send it within 24 h →
Description
What this equipment is and what it's designed for.
Outline
This simulator is a realistic full-term male newborn baby with anatomical accuracy and product features designed to focus on the critical resuscitation skills required in the first ten minutes of a newborn’s life, it meets the key components of the Neonatal Resuscitation Program and most other neonatal clinical training curricula.
Skills Gained
Infant CPR
Tracheal intubation
Positive pressure ventilation
Sellick maneuver
Airway clearance
Umbilical vein intubation and administration
Infant holding method
Features
Anatomy
Baby: anterior fontanel, posterior fontanel, inferior angle of scapula, umbilical cord, genitalia, etc.
Flexible joints such as bilateral shoulder, elbow, hip, etc.
Airway: tongue, palate, epiglottis, esophagus upper orifice , vocal cords, trachea, etc.
Realism: realistic tactile impression
Key Features:
- Flexible joints allow for pronation and supination of the limbs.
- If the newborn’s head is not supported when being held, the neck may display a hyperextension effect, and the newborn’s head may passively complete the extension, pitching and bending motions.
- The model can be placed in the nasal aspiration position, and a 10F suction tube can clear the airway through the mouth and nose.
- The contours of the face can fit well with the mask to ensure no air leakage during ventilation.
- The accurate airway structure fully shows the characteristics of newborns, the epiglottis is long with a clockwise rotating “C” shape, and the epiglottis is above the oral axis, and the epiglottis is above the oral axis. Tracheal intubation can be accomplished with a 3.0 mm endotracheal tube (without cuff). The head can be tilted back to open the airway and the glottis can be easily visualized during the sellick maneuver.
- Positive-pressure ventilation can be performed using BVM. It can also be operated by connect a bag after successful tracheal intubation.
- The model can be connected with T-piece resuscitator for continuous positive pressure ventilation. The error range between the detected PIP, PEEP by the T-piece and correction value is not more than ±2.
- Neonatal chest compression can be performed, the compression depth should be at least one-third of the anterior and posterior diameter of the thorax, and two thumb-encircling hands technique can be practiced.
- The simulated umbilical cord contains 2 umbilical arteries and 1 umbilical vein that can be seen in the cross-section, the simulated blood can flow out continuously. The umbilical artery can be palpated. Intubation is available in umbilical vein, the depth of intubation should not be less than 5 cm below the root of the umbilicus. It supports the operation of real drug administration in umbilical vein.
- The umbilical cord is replaceable, can be cut, and supports ligation and stump care.
- Various clinical operation scenarios are supported.
Specifications
- Gross weight (kg): 4.5
- Packing size (cm): 58 x 37 x 26
- Product size(mm): 580*370*260
What you learn
Task trainer modality. The competencies this equipment trains, in the language of the training plan.
- Realizar la RCP del lactante con la técnica de los dos pulgares.
- Ventilar con presión positiva con bolsa autoinflable y con pieza en T.
- Intubar la tráquea del recién nacido.
- Aplicar la maniobra de Sellick.
- Desobstruir la vía aérea por la boca y por la nariz.
- Canalizar la vena umbilical y administrar fármacos.
Related procedures: Airway management · Basic life support · TNG / Tracheotomy · Umbilical catheterisation
Cases and pathologies
The clinical scenarios that can be simulated with this equipment.
- Reanimación en los diez primeros minutos de vida.
- Necesidad de ventilación con presión positiva continua.
- Obstrucción de la vía aérea por secreciones.
- Administración de fármacos por vía umbilical.
- Hiperextensión del cuello al coger al recién nacido sin sujetar la cabeza.
Features and what's included
What the equipment does and what comes in the box, as described by the manufacturer.
Features
- Recién nacido varón a término, anatómicamente preciso.
- Vía aérea neonatal con epiglotis larga en forma de C rotada.
- El contorno de la cara se adapta a la mascarilla sin fugas de aire.
- Cordón umbilical recambiable, con dos arterias y una vena.
- Articulaciones flexibles que permiten la pronación y la supinación.
- Cumple los puntos clave del Programa de Reanimación Neonatal.
Services for this equipment
Services matter: the equipment gets commissioned, the staff know how to use it and maintenance is settled before you start. Include them in your budget and avoid having to raise a second purchase.
- Preventive maintenance We'll let you know when it's due
Documentation
You can download it now or we'll send it on request.
Other related equipment
They train the same technique. Each one approaches it in its own way: none of them replaces this one.
-
Child CPR/Airway Management Torso
See details →
-
Infant Airway Obstruction and CPR Simulator
See details →
-
Newborn Nursing Skills and ALS Simulator
See details →
-
HAL EMERGENCY AIRWAY & CPR - OMNI2
See details →
-
NEWBORN ANGEL - Newborn simulator for vascular and umbilical access
See details →
-
Adult Airway Management Trainer
See details →
Is this equipment going into a new centre?
If you're equipping a classroom or a whole centre, starting from the shopping list works out expensive. Start from the needs assessment.