Reference 01127 · Patient simulator
Birth and obstetric manoeuvres simulator - Victoria
- Patient simulator
- Obstetrics
- Main product
- Medicine
VICTORIA S2200 is the most advanced labour and delivery patient simulator in the world, designed for simulation-based education and training of students and professionals in maternal-fetal care, high-risk deliveries, postpartum emergencies, and much more.
Price on request
Available in Spain, Portugal and Andorra · delivery time given in the proposal
Downloadable data sheet — features, specifications and delivery time, in PDF.
Need a technical report? Ask us for it and we'll send it within 24 h →
Description
What this equipment is and what it's designed for.
From early pregnancy complications, high-risk deliveries and postpartum emergencies to non-gravid scenarios for general nursing care, VICTORIA simulates a full range of obstetric events to facilitate teamwork and deepen critical thinking skills in learners at all levels.
More than a birth simulator, VICTORIA is a complete simulation solution developed from decades of obstetric experience.
It is a complete package of tools and support designed to help improve patient safety in women’s health through education and training.
VICTORIA redefines physical fidelity with anatomically accurate proportions that facilitate learning without compromising clinical technique. The soft, full-body skin provides a look and feel designed to immerse learners in simulation.
What you learn
Patient simulator modality. The competencies this equipment trains, in the language of the training plan.
- Critical thinking
- General obstetric care
- General nursing care
- Early pregnancy complications
- High-risk deliveries
- Postpartum emergencies: haemorrhage, haemorrhagic lateral vaginal tears and cervical lacerations
- Teamwork
- Seizure management
- Normal, breech, shoulder dystocia, vertex and caesarean births
- Gynaecology
- Oral, nasal and/or oesophageal intubation
- Defibrillation, cardioversion and pacing
- BVM ventilation
- Auscultation of neonatal heart and lung sounds
- Leopold manoeuvres
- McRoberts manoeuvre
- Bladder catheterisation
Related procedures: Childbirth
Cases and pathologies
The clinical scenarios that can be simulated with this equipment.
- Early pregnancy complications
- High-risk delivery
- Shoulder dystocia
- Umbilical cord prolapse
- Postpartum haemorrhage
- Postpartum emergencies
- Non-pregnancy scenarios of general nursing care
Features and what's included
What the equipment does and what comes in the box, as described by the manufacturer.
Features
PRODUCT FEATURES:- Tetherless and wireless; fully responsive during transport
- Internal rechargeable battery provides up to 10 hr. of tetherless operation
- Smooth and supple full-body skin with seamless articulating joints
- Lifelike joint articulation: neck, shoulder, elbow, wrist, hip, knee, and ankle
- Internal high-capacity fluid reservoirs
- NOELLE® Fetus-Newborn wireless link capability
- Includes touchscreen tablet PC preloaded with UNI®
- Includes touchscreen virtual patient monitor and CTG
- Programmable blinking rate, pupil response, and bilateral and unilateral eye movement
- Interactive eyes can follow a moving object
- Seizures with selectable intensity levels
- Wireless streaming voice: be the voice of VICTORIA and listen to participants’ responses via a wireless headset
- Record and playback vocal responses in any language
- Head tilt/chin lift/jaw thrust
- Oral or nasal intubation
- Difficult airway: laryngospasm, tongue oedema, and pharyngeal swelling
- Airway intubation depth detection, logging, and reporting
- Oesophageal intubation
- Selectable upper airway sounds synchronized with breathing patterns
- Supports BVM and mechanical ventilation
- Spontaneous breathing; selectable respiratory patterns and lung sounds
- Programmable respiratory rates and inspiratory/expiratory ratios
- Realistic chest rise during assisted ventilation
- Ventilation performance, real-time monitoring, reporting, and logging
- Right mainstem intubation detection with automatic unilateral chest rise
- Real CO2 exhalation capable (CO2 Adapter S2200.078)
- eCPRTM Real-time compression and ventilation performance
- Effective compressions generate palpable pulses and ECG artifacts
- Select from an extensive library of preprogrammed heart rhythms with dysrhythmia options
- Real-time 4-Lead electrocardiogram monitoring using real ECG devices
- Defibrillation, cardioversion, and pacing using real energy
- Realistic heart sounds
- Programmable heart rate synchronized with ECG and pulses, even during pacing
- Display virtual 12-lead dynamic ECG rhythms
- Bilateral palpable carotid, radial, and brachial pulses are synchronized with heart rate and blood pressure
- Monitor oxygen saturation using real oximeters
- Measure blood pressure using a real manual or automatic blood pressure cuff
- Bilateral venous access
- Automatic drug recognition detects medication type, dose, and rate injected into the lower right arm
- SubQ and intramuscular injection sites for placement exercises
- Maternal-fetal physiologic link
- Supports Leopold’s Manoeuvres and external cephalic version
- Supports fetal monitoring using real devices
- Precision Delivery System: computer-controlled fetal descent and cardinal movements
- Programmable normal, breech, shoulder dystocia, instrument-assisted delivery, and C-section
- Software activated self-lubricating birth canal
- Realistic placenta with detachable fragments and umbilical cord
- Epidural placement and needle detection; palpable anatomical landmarks and skin layers
- Intrapartum bleeding
- Force sensor reports traction and torsion applied to the fetus in real-time
- McRoberts manoeuvre, suprapubic pressure, Zavanelli, Woods’ Screw, and “hands and knees” position detection
- Births full-term neonate of realistic size and weight
- Active neonate: programmable heart and respiratory sounds, crying, cyanosis, and movement
- Replaceable episiotomy inserts support suturing
- Multi-layer fourth-degree episiotomy with haemorrhaging vaginal sidewall tears and cervical lacerations
- Programmable uterine firmness and haemorrhaging; supports sutures and balloon tamponade
- Programmable haemorrhage flow control
- Selectable bowel sounds
- Internal fluid bladder with urethra for Foley catheterisation exercises
- Rectum with suppository placement sensor
- Fully programmable physiological parameters of airway, breathing and circulation.
- Realistic birth of a full-term baby with programmable vital signs for APGAR scoring.
- Integrated sensor suite monitors participant performance in real time.
- Automatic recognition of over 50 virtual medications.
- Wireless and cordless; up to 10 hours of battery life.
- Compatible with real monitoring equipment: EKG, capnograph, defibrillator, NIBP, TOCO and pulse oximeters.
- Includes 9 Simulated Labour Learning Experiences (SLE).
- Training video library on set-up and operation.
- Becomes a non-pregnant patient for general nursing and gynaecology training.
- Soft and supple full body skin with seamless joints.
- Realistic articulation of joints: neck, shoulders, elbows, wrists, hips, knees and ankles.
- Large capacity internal fluid reservoirs
- Selectable upper airway sounds synchronised to breathing patterns
- Programmable blink rate, pupillary response and bilateral and unilateral eye movement.
- Interactive eyes can follow a moving object and realistic eye movements.
- Seizures with selectable intensity levels
- Wireless voice transmission: be the voice of VICTORIA and listen to participants' responses through wireless headphones
- Record and play back vocal responses in any language
- Head tilt/chin lift/jaw thrust
- Oral, nasal and/or oesophageal intubation
- Difficult airway: laryngospasm, lingual oedema, pharyngeal swelling
- Detection, recording and reporting of depth of airway intubation
- Compatible with BVM and mechanical ventilation
- Spontaneous breathing; selectable breathing patterns and lung sounds
- Programmable breathing rates and inspiratory/expiratory ratios
- Realistic chest rise during assisted ventilation
- Ventilation performance, real-time monitoring, reporting and logging
- Right main trunk intubation detection with automatic unilateral chest rise
- Realistic CO2 exhalation capability
- eCPR™ Real-Time Compression and Ventilation Performance
- Efficient compressions generate palpable pulses and ECG artefacts
- Choice of an extensive library of pre-programmed cardiac rhythms with dysrhythmia options
- Real-time 4-lead ECG monitoring using real ECG devices
- Defibrillation, cardioversion and real-energy pacing
- Realistic heart sounds
- Programmable heart rate synchronised with ECG and pulses, even during pacing
- Display of virtual dynamic 12-lead ECG rhythms
- Palpable bilateral carotid, radial and brachial pulses are synchronised with heart rate and blood pressure
- Oxygen saturation monitoring with real oximeters
- Blood pressure measurement with a real manual or automatic blood pressure cuff
- Bilateral venous access
- Automatic drug recognition detects drug type, dose and injection rate on the right lower arm
- Subcutaneous and intramuscular injection sites for positioning exercises
- Physiological maternal-fetal bonding
- Supports Leopold's manoeuvres and external cephalic version
- Supports fetal monitoring using real devices
- Precision delivery system: computer-controlled fetal descent and cardinal movements
- Software-activated self-lubricating birth canal
- Realistic placenta with detachable fragments and umbilical cord
- Epidural placement and needle detection; anatomical landmarks and palpable skin layers
- Intrapartum haemorrhage
- Force sensor reports traction and torque applied to the foetus in real time
- McRoberts manoeuvre, suprapubic pressure, Zavanelli, Woods Screw and "hands and knees" position detection
- Full-term neonate of realistic size and weight
- Active neonate: programmable heart and breath sounds, crying, cyanosis and movement
- Replaceable episiotomy inserts facilitate suturing
- Multilayered fourth-degree episiotomy with haemorrhagic vaginal lateral tears and cervical lacerations
- Programmable uterine firmness and bleeding; supports sutures and balloon tamponade
- Programmable control of haemorrhagic flow
- Selectable bowel sounds
- Internal bladder with urethra for Foley catheterisation exercises
- Rectum with suppository placement sensor
Includes
- Victoria simulator
- Newborn simulator
- Includes touchscreen tablet PC preloaded with UNI
- Virtual patient monitor with touchscreen and CTG
Consumables and spare parts
What this equipment will need next year.
-
Mineral oil Mineral oil. Original consumable, compatible with the patient simulators VICTORIA, HAL AI, HAL, PED HAL, PREMIE HAL and SUPER TORY.14002
-
Mineral oil (gallon) for Ref. 1127 and 1141 Mineral oil (gallon). Original consumable, compatible with VICTORIA (Ref. 1127) and SUPER OB SUSIE (Ref. 1141).14003
-
Placenta for Ref. 1127 and 1141 Placenta. Original replacement part, compatible with VICTORIA (Ref. 1127) and SUPER OB SUSIE (Ref. 1141).14009
-
Umbilicus stump for Ref. 1127 and 1141 Umbilicus stump. Original replacement part, compatible with VICTORIA (Ref. 1127) and SUPER OB SUSIE (Ref. 1141). Set of 2.14013
-
VICTORIA - 10-12 week pregnant cervix 10-12 week pregnant cervix. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).13992
-
VICTORIA - 4th degree episiotomy Fourth-degree episiotomy insert for the VICTORIA obstetric-birth simulator.01710
-
VICTORIA - 6-8 week pregnant cervix 6-8 week pregnant cervix. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).13993
-
VICTORIA - Abnormal cervix set of 6 Abnormal cervix set of 6. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).13994
-
VICTORIA - Antecubital veins for IV Replacement antecubital veins for IV practice on the VICTORIA obstetric-birth simulator.01716
-
VICTORIA - Anteverted uterus with removable adnexa Anteverted uterus with removable adnexa. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).13996
-
VICTORIA - C-section uterine layer C-section uterine layer. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).13997
-
VICTORIA - Caesarean section insert Caesarean-section insert for the VICTORIA obstetric-birth simulator.01711
-
VICTORIA - Cervix Replacement cervix for the VICTORIA obstetric-birth simulator. Replaced when it loses elasticity after repeated use.01714
-
VICTORIA - Epidural insert Replacement epidural insert for the VICTORIA obstetric-birth simulator.01707
-
VICTORIA - Fully dilated birthing cervix Fully dilated birthing cervix. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).13998
-
VICTORIA - Latex-free antecubital veins Latex-free antecubital veins. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).13995
-
VICTORIA - Left arm Left arm. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).14000
-
VICTORIA - Left arm skin cover with SpO2 sensor Left arm skin cover with SpO2 sensor. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).13999
-
VICTORIA - Mediolateral left episiotomy Mediolateral left episiotomy. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).14001
-
VICTORIA - Midline episiotomy Midline episiotomy insert for the VICTORIA obstetric-birth simulator.01708
-
VICTORIA - Non-pregnant abdomen fallopian tubes Non-pregnant abdomen fallopian tubes. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127). Set of 2.14004
-
VICTORIA - Non-pregnant abdomen IUD uterus Non-pregnant abdomen IUD uterus. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).14005
-
VICTORIA - Non-pregnant abdomen ovaries Non-pregnant abdomen ovaries. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127). Set of 2.14006
-
VICTORIA - Non-pregnant abdomen perineum Non-pregnant abdomen perineum. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).14007
-
VICTORIA - Normal cervix Normal cervix. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).14008
-
VICTORIA - Retroverted uterus with removable adnexa Retroverted uterus with removable adnexa. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).14010
-
VICTORIA - Simulated blood concentrate Simulated blood concentrate. Original consumable, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).14011
-
VICTORIA - Skin for right arm Replacement skin for the right arm of the VICTORIA obstetric-birth simulator.01713
-
VICTORIA - Syringe labels (100pcs/set) Replacement identification labels for syringes used with the VICTORIA obstetric-birth simulator, set of 100 units.01720
-
VICTORIA - Umbilical cord (2pcs/set) Replacement umbilical cord for the VICTORIA obstetric-birth simulator, set of 2 units.01715
-
VICTORIA - Umbilical cord set Umbilical cord set. Original replacement part, compatible with the VICTORIA obstetric birthing simulator (Ref. 1127).14012
Services for this equipment
Services matter: the equipment gets commissioned, the staff know how to use it and maintenance is settled before you start. Include them in your budget and avoid having to raise a second purchase.
- Installation and setup Technician · at your centre
- Equipment usage training Trainer · at your centre
- Preventive maintenance We'll let you know when it's due
Documentation
You can download it now or we'll send it on request.
Other related equipment
They train the same technique. Each one approaches it in its own way: none of them replaces this one.
-
26-week premature birthing simulator - Baby Lara
See details →
-
26-week premature birthing simulator - Baby Lulu
See details →
-
26-week premature birthing simulator with gastroschisis - Baby Libby
See details →
-
35-week premature birthing simulator - Baby Aiden
See details →
-
40-week full-term birthing simulator - Baby Nina
See details →
-
40-week full-term birthing simulator with cleft lip - Baby Nina
See details →
Is this equipment going into a new centre?
If you're equipping a classroom or a whole centre, starting from the shopping list works out expensive. Start from the needs assessment.