Skip to content

Reference 01499 · Patient simulator

Eigenflow 2 - ECMO expert training

  • Patient simulator
  • Cardiology
  • Main product
  • Medicine

At the forefront of new medical simulators, EigenFlow addresses the need for high quality ECMO simulation.
Training nurses and respiratory therapists can be very challenging. ECMO Specialists must be attentive to even the slightest changes in the oxygenator circuit, be able to quickly evaluate problems, and take corrective actions.

Price on request

Available in Spain, Portugal and Andorra · delivery time given in the proposal

Download data sheet

Downloadable data sheet — features, specifications and delivery time, in PDF.

Need a technical report? Ask us for it and we'll send it within 24 h →

Catalogue

Description

What this equipment is and what it's designed for.

At the forefront of new medical simulators, EigenFlow addresses the need for high quality ECMO simulation.

Training nurses and respiratory therapists can be very challenging. ECMO Specialists must be attentive to even the slightest changes in the oxygenator circuit, be able to quickly evaluate problems, and take corrective actions.

Knowledge

What you learn

Patient simulator modality. The competencies this equipment trains, in the language of the training plan.

  • ECMO procedure room setup
  • Management of ECMO complications
  • Team training and effective communication exercises
  • Cannulation and neck incision exercises required during ECMO.

Related procedures: ECMO

Knowledge

Cases and pathologies

The clinical scenarios that can be simulated with this equipment.

THROMBUS:
  • Generate variable flows and pressures with two variable controlled valves for inlet or outlet obstruction, thrombi, kinking, pump chatter, catheter malposition, and variable pre and post oxygenator pressures.
AIR EMBOLUS:
  • Inject small (5cc), medium (25cc), or large (50cc) emboli of free air into an ECMO circuit.
  • Train students when to spot and eliminate an embolus before it becomes fatal.
HYPOVOLEMIA:
  • Drain up to 1 liter of fluid into EigenFlow's internal reservoir then refill the circuit back up when you are done.
Catalogue

Features and what's included

What the equipment does and what comes in the box, as described by the manufacturer.

Features

GENERAL:
  • EigenFlow 2 Advanced is a multifunction wireless ECMO simulator ideal for in situ training of perfusionists and ECMO specialists.
  • Simply interpose the EigenFlow into your existing adult or pediatric ECMO circuit and remotely simulate thrombi, line obstruction, air emboli, hypovolemia, and changes in pulmonary and cardiac function.
WIRELESS CONTROL FROM YOUR SMARTPHONE:
  • At the heart of EigenFlow is an intuitive iOS interface available for free from the App Store.
  • Rather than tethering control of the EigenFlow to desktop computers, we developed an intuitive iPhone/iPad app that wirelessly controls the EigenFlow.
  • With one hand, controlling EigenFlow it allows control of manikin vitals with the other.
  • EigenFlow connects wirelessly through Bluetooth, so you can control simulations from up to 30m.
BLOOD MONITORING:
  • Display simulated vital blood parameters PaO2, SvO2, Hb, Hct, arterial and venous temperatures, and activated clotting time directly to the ECMO operator.
  • To connect the EigenFlow to your ECMO circuit simple modifications to your existing ECMO circuit are required.

Includes

  • 1 ECMO Simulation trainer
  • 1 Power supply
  • 1 Instructions manual
Catalogue

Modules

They extend what this equipment teaches. They are requested separately and are not included in the quotation by default.

EIGENFLOW 2 ADVANCED (option):
  • With the newly featured Advanced model EigenFlow now features 12 built in scenarios and a variety of new blood parameters.
CANNULATION (option):
  • The 3-Dmed® ECMO cannulation kit provides a realistic experience when training for an ECMO procedure.
  • Surgeons now have an active part in the simulation.
  • The ECMO neck pad allows for a surgical incision, cannulation of vessels and connection to the ECMO circuit for artificial blood transference through the machine
Technical

Services for this equipment

Services matter: the equipment gets commissioned, the staff know how to use it and maintenance is settled before you start. Include them in your budget and avoid having to raise a second purchase.

  • Preventive maintenance We'll let you know when it's due
Technical

Documentation

You can download it now or we'll send it on request.

Catalogue

Other related equipment

They train the same technique. Each one approaches it in its own way: none of them replaces this one.

See ECMO →

Is this equipment going into a new centre?

If you're equipping a classroom or a whole centre, starting from the shopping list works out expensive. Start from the needs assessment.

See the methodology

Measurement cookies

We use Google Analytics to see which equipment gets looked at and to improve the catalogue. We load nothing until you say yes, and you can change your mind whenever you like. Cookie policy