Skip to content
Newborn HAL - Full-term newborn patient simulator

Reference 01512 · Patient simulator

Newborn HAL - Full-term newborn patient simulator

  • Patient simulator
  • Intensive Care Medicine
  • Main product
  • Medicine

Newborn HAL’s® true-to-life physical and physiological features, wireless mobility, and ease-of-use allow you to simulate realistic clinical cases. Whether training occurs in a simulation centre, in situ, or in transit, participants of any level can practice the skills needed to provide safe and effective care to neonatal patients.

Price on request

Available in Spain, Portugal and Andorra · delivery time given in the proposal

Download data sheet

Downloadable data sheet — features, specifications and delivery time, in PDF.

Need a technical report? Ask us for it and we'll send it within 24 h →

Knowledge

What you learn

Patient simulator modality. The competencies this equipment trains, in the language of the training plan.

Related procedures: Airway management · Basic life support · Patient care

Catalogue

Features and what's included

What the equipment does and what comes in the box, as described by the manufacturer.

Features

GENERAL:
  • Available in multiple skin tones
  • Tetherless and fully responsive even while being transported
  • Powered from an internal rechargeable battery or wall outlet
  • Battery capable of 300 recharges; operate the simulator for up to 4 hours
  • Training Guide with both basic and advanced interactive scenarios
  • Use pre-programmed scenarios, modify them, or create your own quickly and easily
  • Installation and training worldwide
  • Simulation Made Easy™
AIRWAY:
  • Multiple upper airway sounds synchronized with breathing
  • Nasal or oral intubation
  • Right mainstem intubation
  • Sensors detect depth of intubation
  • Airway may be obstructed
  • Block right lung, left lung, or both lungs
  • Head tilt/ chin lift
  • Jaw thrust
  • Simulated suctioning techniques can be practiced
  • Bag-Valve-Mask Ventilation
  • Placement of conventional airway adjuncts
  • Endotracheal intubation using conventional ETTs
  • Sellick manoeuvre brings vocal cords into view
CIRCULATION:
  • Measure blood pressure by palpation or auscultation
  • Use real modified BP cuff to measure blood pressure
  • Korotkoff sounds audible between systolic and diastolic pressures
  • Pulse sites synchronized with BP and heart rate
  • Bilateral IV arms with fill/drain sites
  • Realistic flashback
  • SubQ and IM injection sites
  • Intraosseous access at tibia
  • Fontanelle, umbilical, and bilateral brachial pulses synchronized with ECG
BREATHING:
  • Control rate and depth of respiration and observe chest rise
  • Automatic chest rise is synchronized with respiratory patterns
  • Select independent left and right upper lung sounds
  • Chest rise and lung sounds are synchronized with selectable breathing patterns
  • Accommodates assisted ventilation, including BVM and mechanical support
  • Ventilations are measured and logged
  • Chest compressions generate palpable blood pressure waveforms and ECG artifacts
  • Detection and logging of ventilations and compressions
  • Simulated spontaneous breathing
  • Variable respiratory rates and inspiratory/expiratory ratios
  • Bilateral chest rise and fall
  • Unilateral chest rise simulates pneumothoraces
  • Normal and abnormal breath sounds
CARDIAC:
  • ECGs are generated in real-time with physiologic variations never repeating textbook patterns
  • Chest compressions are measured and logged
  • ECG monitoring using real devices; apply real electrodes to conductive skin regions
  • Multiple heart sounds, rates, and intensities
  • Heart sounds synchronized with ECG
  • Dynamic 12-lead ECG display with optional Vital Signs Monitor
SPEECH:
  • Pre-recorded crying
ARTICULATION AND MOVEMENT:
  • Seizure/convulsions
  • Muscle tone active, right arm only, left arm only, reduced and limp
  • Realistic rotation of the shoulder and hip joints
  • Legs bend at the knees
  • Supine or semi-recumbent positions
OTHER:
  • Central cyanosis
  • Colour and vital signs respond to hypoxic events and interventions
  • Fill bladder and perform Foley catheterisation
  • Interchangeable genitalia
  • Umbilical catheterisation
  • Umbilicus with two arteries and one vein – even practice cutdowns
  • Temperature probe placement
  • Insert feeding tubes
  • Auscultate bowel sounds
  • Remains fully functional even while in transit
  • Sensors track student actions
  • Changes in condition and care provided are time-stamped and logged
  • View the actions of up to six care providers using a responsive menu or write your own narrative
  • Generate and share diagnostic lab results
  • File sharing through Vital Signs Monitor
  • Links with optional recording and debriefing system integrating the event log with cameras and patient monitor
  • Supplied with wireless tablet PC
  • Create your own scenarios - add/edit
  • Change simulator’s condition during the scenario
Catalogue

Consumables and spare parts

What this equipment will need next year.

  • Battery for Ref. 1511 and 1512 Battery. Original replacement part, compatible with PED HAL (Ref. 1511) and Newborn HAL (Ref. 1512).
    14085
  • Newborn HAL - I/O tibia bones I/O tibia bones. Original replacement part, compatible with the Newborn HAL full-term newborn simulator (Ref. 1512).
    14096
  • Newborn HAL - Intraosseous leg skin cover Intraosseous leg skin cover. Original replacement part, compatible with the Newborn HAL full-term newborn simulator (Ref. 1512). Set of 2.
    14095
  • Newborn HAL - Left arm Left arm. Original replacement part, compatible with the Newborn HAL full-term newborn simulator (Ref. 1512).
    14097
  • Newborn HAL - Left IV arm skin Left IV arm skin. Original replacement part, compatible with the Newborn HAL full-term newborn simulator (Ref. 1512).
    14098
  • Newborn HAL - Left leg skin Left leg skin. Original replacement part, compatible with the Newborn HAL full-term newborn simulator (Ref. 1512).
    14099
  • Newborn HAL - Oil kit Oil kit. Original consumable, compatible with the Newborn HAL full-term newborn simulator (Ref. 1512).
    14102
  • Newborn HAL - Right arm Right arm. Original replacement part, compatible with the Newborn HAL full-term newborn simulator (Ref. 1512).
    14100
  • Newborn HAL - Right IV arm skin Right IV arm skin. Original replacement part, compatible with the Newborn HAL full-term newborn simulator (Ref. 1512).
    14101
Technical

Services for this equipment

Services matter: the equipment gets commissioned, the staff know how to use it and maintenance is settled before you start. Include them in your budget and avoid having to raise a second purchase.

  • Preventive maintenance We'll let you know when it's due
Technical

Documentation

You can download it now or we'll send it on request.

Catalogue

Other related equipment

They train the same technique. Each one approaches it in its own way: none of them replaces this one.

See Airway management →

Is this equipment going into a new centre?

If you're equipping a classroom or a whole centre, starting from the shopping list works out expensive. Start from the needs assessment.

See the methodology

Measurement cookies

We use Google Analytics to see which equipment gets looked at and to improve the catalogue. We load nothing until you say yes, and you can change your mind whenever you like. Cookie policy