Skip to content

Reference 10854 · Task trainer

Female Catheterization Trainer

  • Task trainer
  • Urology
  • Main product
  • Nursing

Overview The model simulates the lower abdomen and pelvis in adult females with true-to-life size and texture of genitals and perineum.The model simulates the lower abdomen and pelvis of an adult female with true-to-life size and texture of pudendum and perineum. It facilitates the practice of catheterization. The trainer meets the guidelines for preventing CAUTI through teaching aseptic insertion

Price on request

Available in Spain, Portugal and Andorra · delivery time given in the proposal

Download data sheet

Downloadable data sheet — features, specifications and delivery time, in PDF.

Need a technical report? Ask us for it and we'll send it within 24 h →

Catalogue

Description

What this equipment is and what it's designed for.

Product No.: PC-NUE004.01

image.png Overview

The model simulates the lower abdomen and pelvis in adult females with true-to-life size and texture of genitals and perineum.The model simulates the lower abdomen and pelvis of an adult female with true-to-life size and texture of pudendum and perineum. It facilitates the practice of catheterization. The trainer meets the guidelines for preventing CAUTI through teaching aseptic insertion techniques. Trainees can experience actual resistance and pressure during simulation. Internal bladder reservoir for standard catheterization exercises.
Aseptic catheterization technique
Withdrawal of catheter
Urinary catheterization
Fluid management
Bladder irrigation
Simulated Urine actually comes out when catheter is inserted 4-6 cm properly.
An external fluid bag provides simulated urine, using non-return valve technology to ensure that the catheter is removed without leakage.
Instead of external fluid bag, built-in fluid reservoir(600ml) can provide simulated urine for multiple trainees’ demand.
Gas or liquid can be input into the simulated bladder to make it inflation so that the catheter can be fixed after the catheterization. After output the gas or liquid during extubation, gently pull the catheter without resistance.

image.pngAnatomy

Allows trainees to learn urinary catheterization techniques specific to the female anatomy includes pudendum, perineum, labia, clitoris, urethral orifice, bladder

image.png Realism

Supple urethra & resistant sphincter providing realistic response.
Flaccid penis with a lifelike movable foreskin for realistic male catheterization.
Increased mobility of the penis gives a more accurate representation of inserting the catheter.
The genitalia are realistically soft and pliable.

image.png Cleaning

Drain all fluid from the product when not in use.
Clean the simulator with a damp cloth, using warm water and neutral detergent. Do not use any abrasive cleaning agents or materials.
Allow trainer to completely dry before storing.
Keep away from sunshine.

Specifications

Package (kg) & Dimension(cm) LxWxH

8.1

51

42

27.5

Knowledge

What you learn

Task trainer modality. The competencies this equipment trains, in the language of the training plan.

  • Prepare the field and apply the aseptic insertion technique.
  • Identify the female urethral meatus and part the labia correctly.
  • Insert the catheter 4 to 6 cm until urine is obtained.
  • Perform bladder irrigation and manage the fluids.
  • Remove the catheter safely.

Related procedures: Catheterization

Knowledge

Cases and pathologies

The clinical scenarios that can be simulated with this equipment.

  • Urinary retention in the woman.
  • Prevention of catheter-associated urinary tract infection.
  • Urine output monitoring in the female inpatient.
Catalogue

Features and what's included

What the equipment does and what comes in the box, as described by the manufacturer.

Features

  • Lower abdomen and pelvis of an adult woman, with external genitalia and perineum of faithful size and texture.
  • Internal bladder reservoir for the usual catheterisation exercises.
  • Simulated urine flows when the catheter is correctly inserted 4 to 6 cm.
  • Realistic resistance and pressure during the manoeuvre.
  • In line with the recommendations for preventing catheter-associated urinary tract infection.
Technical

Services for this equipment

Services matter: the equipment gets commissioned, the staff know how to use it and maintenance is settled before you start. Include them in your budget and avoid having to raise a second purchase.

  • Preventive maintenance We'll let you know when it's due
Technical

Documentation

You can download it now or we'll send it on request.

Catalogue

Other related equipment

They train the same technique. Each one approaches it in its own way: none of them replaces this one.

See Catheterization →

Is this equipment going into a new centre?

If you're equipping a classroom or a whole centre, starting from the shopping list works out expensive. Start from the needs assessment.

See the methodology

Measurement cookies

We use Google Analytics to see which equipment gets looked at and to improve the catalogue. We load nothing until you say yes, and you can change your mind whenever you like. Cookie policy