Nearly one out of every eight newborns arrive prematurely. To help you give your tiniest patients the best care possible, we are proud to introduce the Micro-Preemie. This 25-week ELBW (Extremely Low Birth Weight) neonate is the smallest and most realistic pre-term infant available.

Price on request

Available in Spain, Portugal and Andorra · delivery time given in the proposal

Download data sheet

Downloadable data sheet — features, specifications and delivery time, in PDF.

Need a technical report? Ask us for it and we'll send it within 24 h →

Catalogue

Description

What this equipment is and what it's designed for.

Nearly one out of every eight newborns arrive prematurely. To help you give your tiniest patients the best care possible, we are proud to introduce the Micro-Preemie. This 25-week ELBW (Extremely Low Birth Weight) neonate is the smallest and most realistic pre-term infant available. Invaluable for training nurses and parents in care and handling techniques for babies that have had multiple medical interventions; the perfect team training aid for multiples or other high-risk delivery and transport scenarios. The baby can be ventilated and will accept a functional ET tube, NG tube, umbilical catheter, and IV line, as well as a non-functional chest tube and stomas. Detachable neural tube defect and omphalocele.

Includes diaper, hat, lubricant, 3 cc syringe, 25 G. butterfly needle and blood powder. Hat color may vary. NG tube size 5 FR. ET tube size 5 mm ID.

Simulator dimensions: 12″ long, 4″ deep, and 18-1/2″ across from hand to hand.

Features and Functions:

  • Breathing – pulse bulb to manually simulate breathing rate volume.
  • Ventilation – molded-in lung produces a visible chest rise when ventilated by mouth; trachea and pharynx are not anatomically correct, but will accept a functioning endotracheal tube.
  • GI – one nostril will accept a functioning NG tube (tube passes through the body and liquids will either drain away from the body or into the diaper); optional stoma can be plugged into a permanent site on the abdomen.
  • Umbilicus – soft, lifelike umbilicus has a patent vein and two arteries; umbilical stump functions like a cork, plugging into a small cavity molded into the abdomen (cavity can be used as a reservoir for blood drawn through a catheter or to receive fluids and the drain exits from the diaper area); a separate umbilicus represents an optional omphalocele.
  • IV Access – several typical sites have embedded tubing that can accept an IV catheter; one is functional, allowing the administration of fluids, which will drain from the diaper area.
  • Chest Tube – a permanent site in the baby’s side accepts a nonfunctioning chest tube.
  • Neural Tube Defect – An optional structure representing an open neural tube defect can be inserted into the back.
  • Various monitors, sensors, electrodes, etc., can be attached to the manikin wherever needed.

Manikin can be used with Supraglottic airway devices for airway training.

Knowledge

What you learn

Patient simulator modality. The competencies this equipment trains, in the language of the training plan.

  • Handling and positioning of the extremely premature baby
  • Care of the newborn undergoing multiple interventions
  • Airway management with supraglottic devices
  • Preparation of the neonate for transport
  • Teamwork in multiple or high-risk births
  • Training of parents in the handling of the premature baby

Related procedures: Airway management · Patient care · TNG / Tracheotomy · Umbilical catheterisation

Knowledge

Cases and pathologies

The clinical scenarios that can be simulated with this equipment.

This simulator makes it possible to work on the scenarios typical of the extremely premature baby:
  • Extreme prematurity at 25 weeks
  • Airway management of the very low birth weight newborn
  • Care after multiple medical interventions
  • Transfer of the critically ill neonate
  • Care in multiple or high-risk births
Catalogue

Features and what's included

What the equipment does and what comes in the box, as described by the manufacturer.

Features

  • Reproduces a 25-week newborn with extremely low birth weight
  • Dark skin tone
  • Compatible with supraglottic airway devices for airway training
  • Designed for training in the care and handling of premature babies
Technical

Services for this equipment

Services matter: the equipment gets commissioned, the staff know how to use it and maintenance is settled before you start. Include them in your budget and avoid having to raise a second purchase.

  • Preventive maintenance We'll let you know when it's due
Technical

Documentation

You can download it now or we'll send it on request.

Catalogue

Other related equipment

They train the same technique. Each one approaches it in its own way: none of them replaces this one.

See Airway management →

Is this equipment going into a new centre?

If you're equipping a classroom or a whole centre, starting from the shopping list works out expensive. Start from the needs assessment.

See the methodology

Measurement cookies

We use Google Analytics to see which equipment gets looked at and to improve the catalogue. We load nothing until you say yes, and you can change your mind whenever you like. Cookie policy