HAL – HI-FI PATIENT SIMULATOR – UNI

PRODUCT NUMBER 1515


HAL – HI-FI PATIENT SIMULATOR – UNI

PRODUCT NUMBER 1515

The HAL®multipurpose patient simulator’s advanced design and tetherless technology eliminate external tubes, wires, and compressors. HAL® operates continuously during transport so that training can occur in the working environment.

Rush HAL® from the accident scene to the ER or the ICU, while care providers diagnose and treat his condition using real monitoring and resuscitation equipment. HAL® smoothly transitions between physiologic states in response to commands from a wireless PC.

DOWNLOAD

* Check availability according to geographic region.

SKILLS

  • Oxygen saturation measurement
  • Blood pressure measurement skills training
  • ECG monitorization and interpretation of waveforms
  • Pupil examination
  • Urinary catheterization
  • IV administration
  • Infusion training
  • Tracheostomy care
  • Needle cricothyrotomy
  • Resuscitation training (CPR)
  • EtCO2 monitoring
  • Defibrillation and pacing training
  • Difficult aiway management

CASES AND PATHOLOGIES

UNI WIRELESS INTERFACE:
  • The UNI® interface design is shared across our growing line of 15+ computer-controlled patient simulators, so you can easily operate any GAUMARD® product without retraining, thus saving your program valuable time and money.
    • Preconfigured and Ready: UNI® comes preloaded and preconfigured on the rugged 12” wireless tablet PC included with the package. 3D Patient Visualization Monitor: This real-time 3D view of the patient ensures you never lose track of provider/patient interaction during the simulation.
    • Scenario Designer: Create your own scenarios quickly and easily and share them with other UNI® users.
    • eCPR™: Monitor rate and compression depth, no-flow time, ventilation rate, and excessive ventilation; smart trainer features vocal cues and outputs performance reports.
      • Lab Report Designer: Generate and share simulated diagnostic lab results to enhance case fidelity and participant involvement.
    • Questionnaire Form Designer: Manage progress by easily creating interactive checklists to track participant objectives and post-simulation feedback.
    • Time-stamped event recording: and reporting The automated event tracking and interaction recorder ensures important events are always captured so you can focus on the action.
    • Provider Actions Tracked: The interactive “Actions” panel lets you carefully track additional team and individual provider actions to generate a comprehensive post-simulation log.
    • UNI® Control View Replay: The built-in recorder captures UNI’s screen as data to allow your team to review the simulation from the operator’s chair.
    • No annual software license fee: GAUMARD® is committed to providing the best value and to keep your program’s operating costs down year after year.
    • Free software updates: Always stay up to date and take advantage of all the newest features at no additional cost.
    • Free webinar training and technical support: Sign up for monthly webinar sessions and become a UNI® expert.
PRE-INSTALLED SCENARIOS:
  • The new HAL® Simulation Learning Experiences (SLEs) provide you with a library of ready-to-use, evidence-based scenarios designed to help you maximize participant’s learning through outcome-focused simulated clinical patient encounters.
  • The package includes 10 SLEs complete with a facilitator’s guidebook for planning, setting up, and facilitating each learning experience:
    • Acute Anterolateral Myocardial Infarction
    • Acute Sepsis Related to Diabetic Ulcer
    • Atrial Fibrillation
    • COPD Exacerbation
    • Diabetic Ketoacidosis
    • Opioid Overdose
    • Pulmonary Embolism
    • Sepsis Related to Pneumonia
    • Severe Sepsis
    • Supraventricular Tachycardia

CHARACTERISTICS

GENERAL:
  • Wireless and tetherless; fully responsive even while being transported
  • Bowel sounds in four quadrants
  • Male urinary catheterization with fluid return
AIRWAY MANAGEMENT:
  • Oral or nasal intubation: ETT, LMA, King LT™, i-gel®
  • Laryngospasm, pharyngeal swelling, tongue edema
  • Intubation depth detection
  • Surgical airway: tracheostomy or needle cricothyrotomy
  • Mainstem intubation
  • Multiple upper airway sounds
BREATHING:
  • Spontaneous breathing and programmable patterns
  • Ventilation is measured and logged
  • Gastric distension with excess BVM ventilation
  • Select independent left, right, upper, and lower lung sounds
  • Chest rise during assisted ventilation
  • Tension pneumothorax and bilateral needle decompression sites
  • Bilateral chest tube sites at 5th intercostal space
NEUROLOGIC:
  • Active Eyes; programmable blink rate, pupil size, and pupil reaction
  • Severe or mild seizures
  • Preprogrammed speech responses
  • Wireless streaming voice; be the voice of HAL® and listen to replies
CIRCULATION:
  • Normal and abnormal heart sounds, rates, and intensities
  • 4-Lead ECG monitoring using real devices; 12-lead ECG capable3
  • eCPR sensors; chest compressions are measured and logged
  • Monitor oxygen saturation using a real oximeter
  • Measurable blood pressure with audible Korotkoff sounds
  • Visible cyanosis
  • Bilateral carotid, radial, brachial, femoral, popliteal, and pedal pulses
  • Bilateral IV sites
  • Optional virtual drug recognition
  • Intraosseous access at tibia
OTHER:
  • Bowel sounds in four quadrants
  • Male urinary catheterizationwith fluid return
 

INCLUDE

  • 1 HAL adult simulator
  • 1 UNI Tablet PC (simulation controller)
  • 1 Automatic physiologic control license
  • 10 Pre-installed simulation scenarios (SLE package)
  • 1 Set of accessories
  • 1 Set of decompression sites
  • 1 Surgical trachea kit
  • 1 Pneumo kit
  • 1 Blood pressure cuf
  • 1 Battery charger
  • 1 Instructions manual

ADDITIONAL MODULES

CO2 EXHALATION MODULE (option):
  • Real CO2 exhalation. 10 programmable levels of CO2 output.
  • Option only available at time of initial purchase.
AUTOMATIC VIRTUAL DRUG RECOGNITION SYSTEM (option):
  • Includes an upgraded arm for virtual medication admnistration exercises wtih automatic recognition system.
TRAUMA LIMBS (option):
  • Amputated leg
  • Amputated arm
BEDSIDE GAUMARD VITALS PATIENT MONITOR (option):
  • It simulates the functionality and look of a real patient monitor, allowing participants to practice data interpretation, documentation, and clinical decision-making skills.
  • Customizable interface can mimic the look of various real patient monitor brands
  • 20+ Dynamic scalars and waveforms including HR, ABP, SpO2, RR, EtCO2, temperature, time, and more
  • Customizable alarms for vital sign parameter high/low threshold
  • Virtual 12-Lead ECG Monitoring
  • Data histogram
  • Built-in virtual defibrillator and pacer
  • Wireless data communication

Description

The HAL®multipurpose patient simulator’s advanced design and tetherless technology eliminate external tubes, wires, and compressors. HAL® operates continuously during transport so that training can occur in the working environment.

Rush HAL® from the accident scene to the ER or the ICU, while care providers diagnose and treat his condition using real monitoring and resuscitation equipment. HAL® smoothly transitions between physiologic states in response to commands from a wireless PC.

The HAL®multipurpose patient simulator’s advanced design and tetherless technology eliminate external tubes, wires, and compressors. HAL® operates continuously during transport so that training can occur in the working environment.

Rush HAL® from the accident scene to the ER or the ICU, while care providers diagnose and treat his condition using real monitoring and resuscitation equipment. HAL® smoothly transitions between physiologic states in response to commands from a wireless PC.

DOWNLOAD

* Check availability according to geographic region.


SKILLS

SKILLS

  • Oxygen saturation measurement
  • Blood pressure measurement skills training
  • ECG monitorization and interpretation of waveforms
  • Pupil examination
  • Urinary catheterization
  • IV administration
  • Infusion training
  • Tracheostomy care
  • Needle cricothyrotomy
  • Resuscitation training (CPR)
  • EtCO2 monitoring
  • Defibrillation and pacing training
  • Difficult aiway management
CASES AND PATHOLOGIES
CHARACTERISTICS
INCLUDE
ADDITIONAL MODULES
Description


Skip to content