Angio Mentor Suite II – Endovascular access

PRODUCT NUMBER 1158


Angio Mentor Suite II – Endovascular access

PRODUCT NUMBER 1158

The ANGIO Mentor II is an excellent A-stationary simulation platform that provides a true-to-life Cath Lab/ Hybrid Operating Room clinical environment, ergonomically designed and optimized for training of interventional teams and communication.

All platforms run our ever-expanding portfolio of 35+ ANGIO Mentor modules, as well as ANGIO Mentor iCase and Procedure Rehearsal Studio.

DOWNLOAD

* Check availability according to geographic region.

SKILLS

  • Practicing various endovascular approaches and using multipleaccess sites
  • Enhancing team training with an X-ray technician
  • Real time creation of continuous fluoroscopy, roadmap, CINE and DSA imaging.
  • Vital signs and ECG monitor reflecting complications or drug administration.
  • Using a real TEE probe to practice maneuvering and image interpretation, as well as team training scenarios
  • Practicing and establishing the ALARA principles
  • Allow the trainee to work without fluoroscopy to become familiar with the anatomy.

CASES AND PATHOLOGIES

BASIC SKILLS:

  • Cardio Basics, EP Basic Skills, Endovascular Basic Skills and C-Arm Basics

PERIPHERAL:

  • SFA, Iliac, Below The Knee, Lower Extremities CTO, HCC, UFE, Renal, Atherectomy, Peripheral Embolization, Embolotherapy, Venous Intervention, Trauma Management and Prostatic Artery Embolization

NEUROVASCULAR INTERVENTIONS:

  • EVAR, TEVAR and Advanced TEVAR

CORONARY INTERVENTIONS:

  • Coronary, Coronary CTO, Coronary Bifurcation and Transradial Coronary

STRUCTURAL HEART DISEASES:

  • LAA Closure, TAVI and ASD/PFO Closure

ELECTROPHYSIOLOGY:

  • Transseptal Puncture, Cardiac Rhythm Management, AF ABlation, 3D EP Mapping and ICE Training

CHARACTERISTICS

IMAGING:

  • C-arm and patient table maneuvering
  • Real time fluoroscopy, cineangiography, DSA and roadmapping
  • Real Time Ultrasound (IVUS, ICE, TEE)
  • TEE probe integration

DEVICE SIMULATION:

  • Five access sites: femoral arteries/veins, subclavian artery/vein, pedal access and radial artery
  • A wide selection of interventional devices
  • Simulated deployment systems are based on actual devices
  • Haptic feedback and realistic device behavior

PATIENT MANAGEMENT:

  • Responsive vital signs monitor
  • Extensive medication panel
  • Complex scenarios with real time complications

EDUCATIONAL FEATURES:

  • Comprehensive performance metrics
  • Unique basic skills modules
  • Self-guided tutorial cases for independent practice
  • 3D views to establish anatomical knowledge

INCLUDE

  • 1 Integrated cart-based system with large storage drawer
  • 1 PC with pre-installed software and licenses
  • 1 Adjustable 49″ Screen monitor for fluoro, 3D and hemodynamic display
  • 1 Adjustable 19″ Screen monitor for basic operation
  • 1 Human patient manikin with 5 access sites covered with a surgical sheet
  • 1 Height adjustable patient table
  • 1 Extendable table
  • 1 Pedal switch
  • Set of tools:
    • 1 8F guiding catheter
    • 1 5F Diagnostic catheter
    • 1 0.035″ wire
    • 1 0.014″ wire
    • 1 Rapid exchange catheter
    • 1 Contrast-injection syringe
    • 1 Stent deployment device
    • 1 Balloon inflator

ADDITIONAL MODULES

ANGIO MENTOR VR (option):

  • ANGIO Mentor training simulators provide a comprehensive, safe environment for multi-level hands-on practice of endovascular procedures and techniques performed in the cath lab, interventional suite or operating room.

C-ARM INTEGRATION (option):

  • Integration of an actual C-arm into the simulation training so that its rotation corresponds with the simulated fluoroscopy view.
  • Physical rotation of the C-arm (LAO/RAO/CRAN/CAUD) is mirrored to the virtual C-arm and shown on the simulation monitor.
  • C-arm integration is especially beneficial for team training as it enables the participation of an x-ray technician to mimic the actual setting and interaction between participants in a real procedure.

REAL-TIME TEE PROBE (option):

  • The addition of the live TEE probe capabilities will allow the trainee to practice trans-Esophageal Echocardiography basic operation, probe maneuvering and image interpretation in addition to a live echo guidance in interventional procedures that require TEE imaging as Transseptal puncture, LAA Closure, ASD/PFO and AF ablation.
  • This new configuration creates a realistic working environment that allows full team training scenarios for different staff members including endovascular operators, x-ray technicians, echographers and nurses.
  • The simulator will now allow not only the training of specific procedural tasks but also enhancing team collaboration and human factor skills, focusing on improving the team work and enhancing the clinical results.
  • Kit includes:
    • Modified TEE probe
    • Probe stand
    • Specific software package

MENTOR LEARN MANAGEMENT SYSTEM (option):

  • Customizable curriculum incorporating training and didactics
  • Easy and efficient administration of simulator users
  • Online learning courses and video-based content
  • Proficiency based hands-on training
  • Performance reports with learning curve graphs
  • Recorded videos of the simulation sessions for debriefing

Description

The ANGIO Mentor II is an excellent A-stationary simulation platform that provides a true-to-life Cath Lab/ Hybrid Operating Room clinical environment, ergonomically designed and optimized for training of interventional teams and communication.

All platforms run our ever-expanding portfolio of 35+ ANGIO Mentor modules, as well as ANGIO Mentor iCase and Procedure Rehearsal Studio.

The ANGIO Mentor II is an excellent A-stationary simulation platform that provides a true-to-life Cath Lab/ Hybrid Operating Room clinical environment, ergonomically designed and optimized for training of interventional teams and communication.

All platforms run our ever-expanding portfolio of 35+ ANGIO Mentor modules, as well as ANGIO Mentor iCase and Procedure Rehearsal Studio.

DOWNLOAD

* Check availability according to geographic region.


SKILLS

SKILLS

  • Practicing various endovascular approaches and using multipleaccess sites
  • Enhancing team training with an X-ray technician
  • Real time creation of continuous fluoroscopy, roadmap, CINE and DSA imaging.
  • Vital signs and ECG monitor reflecting complications or drug administration.
  • Using a real TEE probe to practice maneuvering and image interpretation, as well as team training scenarios
  • Practicing and establishing the ALARA principles
  • Allow the trainee to work without fluoroscopy to become familiar with the anatomy.
CASES AND PATHOLOGIES
CHARACTERISTICS
INCLUDE
ADDITIONAL MODULES
Description


Skip to content