RHEXIS – Cenário de capsulorrexe

Nº DE PRODUTO 1680


RHEXIS – Cenário de capsulorrexe

Nº DE PRODUTO 1680

Ao apresentar os principais desafios de um cenário de capsulorrexe, a tarefa RHEXIS permite aos utilizadores aprender, treinar e aperfeiçoar as capacidades motoras finas necessárias para utilizar corretamente a ferida como ponto de apoio para o movimento do instrumento; uma competência fundamental em cirurgia oftalmológica.

Suporte Recomendado: MINI-HOLDER e ROMANO

DESCARREGAR

* Check availability according to geographic region.

HABILIDADES

  • Improve your control by creating a centered and circular rhexis (capsulorhexis scenario)
  • Intraocular instrument manouvering skills
  • Improve your technique by working through a fragile wound
  • Gain confidence and motion control as you decrease time to completion

CASOS E PATOLOGIAS

Avalie a tarefa revendo os seguintes parâmetros:
  • INTEGRIDADE DA INCISÃO: A integridade da ferida está relacionada com a boa técnica na manipulação de instrumentos através de pontos de acesso, uma competência fundamental da cirurgia oftalmológica. A dimensão consistente da rexe é um indicador de boa técnica e compreensão da escala.
  • CENTRALIZAÇÃO DA REXE: Embora por vezes se deseje um desvio (nasal e superior) em casos reais, para efeitos de formação e avaliação de tarefas, uma rexe centrada é conveniente para pontuar com instrumentação simples. Uma rexe centrada mostra controlo do contexto cirúrgico.
  • TEMPO ATÉ À CONCLUSÃO: Embora em situações cirúrgicas reais a qualidade seja mais importante do que a velocidade, a um nível de formação de competências básicas, o tempo até à conclusão é um bom indicador de uma curva de aprendizagem. À medida que a familiaridade com as etapas e a confiança na técnica aumenta, espera-se uma diminuição do tempo até à conclusão.

Características

SETUP WITH ORBIT HOLDER:
  1. Insert the RHEXIS model in the ORBIT Model Eye Holder (compatible with BASIC-ORBIT and FLEX-ORBIT). Be careful not to damage delicate structures when inserting the models.
  2. Use a broad-tip sharpie, to color the tip of a dry cotton swab; add a couple of water drops to the capsule and then gently remove the excess water with the stained swab. This will lubricate the model and lightly stain the capsule.
  3. Make an incision on the limbus with your knife of choice. Entry depth, angle and incision width can be demonstrated and practiced. NOTE: The model promotes the user to create and work from a posterior incision.
  4. Start a capsule tear with acystotome. NOTE: Make the flap broad so it is easy to grasp with the forceps. The capsule in the model is more fragile than the real capsule and requires a fuller bite with the forceps.
  5. Manipulate the Utrata forceps of choice through the port to create a continuous circular tear on the capsule. NOTE: The model promotes frequent regrasping and gentle manipulation of the forceps. Breakage of the capsule flap can result if a long tear is attempted without regrasping. The capsule may be cut by the forcepsif the pinching force is too high.

INCLUI

  • 10 capsulorrexe simulador de olho
  • 1 caixa de armazenamento

Descrição

Ao apresentar os principais desafios de um cenário de capsulorrexe, a tarefa RHEXIS permite aos utilizadores aprender, treinar e aperfeiçoar as capacidades motoras finas necessárias para utilizar corretamente a ferida como ponto de apoio para o movimento do instrumento; uma competência fundamental em cirurgia oftalmológica.

Suporte Recomendado: MINI-HOLDER e ROMANO

Ao apresentar os principais desafios de um cenário de capsulorrexe, a tarefa RHEXIS permite aos utilizadores aprender, treinar e aperfeiçoar as capacidades motoras finas necessárias para utilizar corretamente a ferida como ponto de apoio para o movimento do instrumento; uma competência fundamental em cirurgia oftalmológica.

Suporte Recomendado: MINI-HOLDER e ROMANO

DESCARREGAR

* Verifique a disponibilidade de acordo com a região geográfica


HABILIDADES

HABILIDADES

  • Improve your control by creating a centered and circular rhexis (capsulorhexis scenario)
  • Intraocular instrument manouvering skills
  • Improve your technique by working through a fragile wound
  • Gain confidence and motion control as you decrease time to completion
CASOS E PATOLOGIAS
Características
INCLUI
Descrição


Skip to content